INSTALLATION AND OPERATING INSTRUCTIONSCBW SERIES RESIDENTIALBACKWASH FILTER SYSTEMSMODELS:CBW1001 CBW1001DM CBW1501 CBW1501DMCBW2001 CBW2001DMInstall
Step 5Loosen set-screw and pull out drain line fl ow control (DLFC) assembly from valve body (see Figure 2). Unscrew drain line elbow from DLFC. Apply
HOW TO SET TIME CONTROLHOW TO SET DAYS ON WHICH FILTER IS TO BACKWASH:Rotate the skipper wheel until the number “1” is at the red pointer. Set the day
HOW TO SET THE BACKWASH CYCLE PROGRAM:The backwash cycle program on your fi lter has been factory preset. However, portions of the cycle or program may
SECTION 4: MAINTENANCEGeneral Maintenance1) At least every six (6) months, you should check the time of day setting. Power outages will cause the uni
5-1SECTION 5: TROUBLESHOOTINGPROBLEM CAUSE SOLUTION1Excessive pressure drop through fi lter.A Filter not backwashing.1 Check timer motor and replace as
6-1SECTION 6: SPECIFICATION AND OPERATING DATAITEM CBW1001 CBW1501 CBW2001Nominal Media Volume, cu. ft. (cu. mtr.) 1.0 (0.03) 1.5 (0.04) 2.0 (0.06)Gra
6-27465132COMPONENT PARTS LIST REF DescriptionCBW1001CBW1001DMCBW1501CBW1501DMCBW2001CBW2001DM1 Control valve, complete, less bypass C210500-003 C2105
6-3CEC1000 SERIES BACKWASH CONTROL
ONLY THOSE PARTS CIRCLED IN DRAWING ON PREVIOUS PAGE AND/OR LISTED BELOW ARE STOCK ITEMS.ALL OTHERS ARE SPECIAL ORDER, NON-RETURNABLE.BACKWASH CONTRO
WIRING DIAGRAM FOR VALVE DRIVE MOTOR AND TIMERCEC1000 SERIES VALVESVALVE MOTORTIMER MOTORPROGRAMWHEELPROGRAMRE-SETSWITCHWHITEBLUERAPID RINSEBRINE TANK
7-1SECTION 7: LIMITED WARRANTYLimited Warranty: 3M Purifi cation Inc. warrants this Product to be free from defects in material and workmanship during
SAFETY INFORMATIONRead, understand, and follow all safety information contained in these instructions prior to installation and use of the Aqua-Pure®
SECTION 1: BEFORE INSTALLATION1-1TABLE OF CONTENTSSECTION DESCRIPTION1 BEFORE INSTALLATION2 INSTALLATION3 BACKWASHING INSTRUCTIONS4 MAINTENANCE5 TROUB
1-2CAUTIONTo reduce the risk associated with property damage due to water leakage:• Do not install system where water lines could be subjected to vac
1-3Facts to Remember While Planning The Installation: 1) All installation procedures MUST conform to local and state plumbing codes. 2) If lawn
2-1SECTION 2: INSTALLATIONProper installation sequence of the backwash fi lter system is very important. Refer to the diagram below for your particular
Step 1a) Remove cardboard die-cut from media tank. b) Remove valve assembly from cardboard die-cut and set aside.c) Remove distributor tube from